PROFInet Type C high flexible (PVC + PUR)

HELUKAT® PROFInet Type C PVC (highly flexible) Category 5e for use on moving parts and in cable carriers. The cable listed here correspond to the PROFInet classifications Type C for moving cables and are designed to withstand mechanical loads. Thanks to the flame retardent jacket the PVC cable has UL CMG PLTC FT4 AWM 600V approval. The PUR version has UL CMX listing and offers higher values in chain and chemical resistance.

Descrição

Type Cable structure Drag chain applications 2x2x0.75 mm (stranded) Drag chain applications 2x2x0.75 mm (stranded)
Inner conductor diameter: Copper, tinned (AWG 22/7) Copper, tinned (AWG 22/7)
Core insulation: PE PE
Core colours: wh, ye, bu, og wh, ye, bu, og
Stranding element: Star quad Star quad
Separator: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: PVC FRNC
Shielding 1: Al-Foil Al-Foil
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PUR
Cable external diameter: app. 6,5 mm ± 0,2 mm app. 6,5 mm ± 0,2 mm
Outer sheath colour: Green similar to RAL 6018 Green similar to RAL 6018
Electrical data Drag chain applications 2x2x0.75 mm (stranded) Drag chain applications 2x2x0.75 mm (stranded)
Characteristic impedance: 100 Ohm ± 15 Ohm at 1 to 100 MHz 100 Ohm ± 15 Ohm at 1 to 100 MHz
Conductor resistance, max.: 60 Ohm/km 60 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km 0,5 GOhm x km
Loop resistance: 120 Ohm/km max. 120 Ohm/km max.
Mutual capacitance: 120 Ohm/km max. 120 Ohm/km max.
Test voltage: 1,5 kV 1,5 kV

Typical values

Frequency (MHz) 10 16 62,5 100
Attenuation (db/100m) 6,3 8,0 16,5 21,3
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 64,0 57,4 39,0 29,0
Technical data Drag chain applications 2x2x0.75 mm (stranded) Drag chain applications 2x2x0.75 mm (stranded)
Weight: app. 68 kg/km app. 61 kg/km
bending radius, repeated: 55 mm 55 mm
Operating temperature range min.: -20°C -30°C
Operating temperature range max.: +70°C +75°C
Caloric load, approx. value: 0,85 MJ/m 0,85 MJ/m
Copper weight: 32,00 kg/km 32,00 kg/km
Norms Drag chain applications 2x2x0.75 mm (stranded) Drag chain applications 2x2x0.75 mm (stranded)
Applicable standards: PROFInet Guideline + IEC 61158-2
Acc. to ISO/IEC 11801
Acc. to EN 50173
Category 5e
Flame-retardant acc. to IEC 60332-3
PROFInet Guideline + IEC 61158-2
Acc. to ISO/IEC 11801
Acc. to EN 50173
Category 5e
Halogen-free acc. to 60754-1
Flame-retardant acc. to IEC 60332-1-2
UL Style: CMG 75°C or PLTC or AWM 21694 600V CMX 75°C (shielded)
CSA standard: CSA FT 4